Viewing Head
With the most suitable viewing degree, 30° inclined head holds everyone in the best working state, less tension and fatigue. The scale on the viewing head is convenient for users to adjust the optimal interpupillary distance.
Vertical Illuminator
Adopting Kohler illumination system, with field diaphragm, aperture diaphragm and oblique illumination device, as well as slots for polarizing kit and filters.
Compared with other LED, single 5W LED with warm white lighting (3000-3300K), minimizes the visual fatigue of the observer.
With pull-rod devices for adjusting the centers of field and aperture diaphragm, stray light can be eliminated by expanding or shrink the illumination zone.
Simple polarizing observation is available with pluggable polarizer kit. You can also choose different filters to obtain the ideal observation effect according to your needs.
Optical system : infinity-corrected optical system
Viewing Head :
30° inclined; Infinity hinge three-way viewing head; the interpupillary distance is adjustable between 54mm - 75mm; diopter adjustment: ±5 diopters; two-level split ratio R:T=100:0 or 50:50
Eyepiece:
High eye-point wide field plan field eyepiece PL10X/22mm
High eye-point wide field plan field eyepiecePL10X/22mm (Adjustable diopter, with micrometer)
High eye-point wide field plan field eyepiecePL15X/16mm
Infinity plan achromatic objective
LMPL 5X /0.15 WD10.8mm
LMPL 10X/0.30 WD12.2mm
LMPL 20X/0.45 WD4.00mm
LMPL 50X/0.55 WD7.9mm
LMPL 100X/0.80 WD2.1mm
Converter : Internal positioning five-hole converter
Focus Adjustment:
Transmitted & Reflected frame, coaxial focus system with tension adjustment and up-limited device, coarse range: 28mm, fine precision: 0.002mm. Stage can be adjusted up and down, 28mm high sample is available.
Reflected frame, coaxial focus system with tension adjustment and up-limited device, coarse range: 28mm, fine precision: 0.002mm.
Stage can be adjusted up and down, 78mm high sample is available.
Stage :
Double layer mechanical stage with X/Y coaxial adjustment, size: 175mmX145mm, moving range: 76mmX42mm.
Metal plate for transmitted frame; glass plate for transmitted & reflected frame.
Reflected illumination:
Wide-range voltage 100V-240V_AC50/60Hz, reflected lamp-house with single 5W LED, warm color. Koehler illuminator with oblique light device,
center adjustable field and aperture diaphragm
Transmitted illumination:
Wide-range voltage 100V-240V_AC50/60Hz, transmitted lamp-house with single 5W LED, warm color.
Condenser:
N.A.0.9 swing-out achromatic condenser for transmitted frame, with center adjustable aperture iris diaphragm.
Filter:
Yellow/neutral/IF550/LBD filter for transmitted light
Metallographic Analysis System:
FMIA2020 Metallographic analysis software; Sony chip 5 million camera device, 0.5X adapter lens interface,
high-precision micrometer (100x0.01mm, 100x0.01cm, calibration: d = 0.15mm, d = 0.07mm)
Computer : HP business PC