Features
● Non-destructive testing the corrosion in rebar.
● Detection of the corrosion condition of the rebar accurately and conveniently by field potential measurement.
● Possibility to store, view, delete data and transfer all readings to PC with USB interface and serial port.
● Faster and more accurate processing of data, presentation of test area and reading as numbers or graphics.
● Display of measurement values in 9 grey-scale or colorful graphics.
● Permanent copper/copper sulphate reference electrodes to measure electrical potentials.
Technical Specification
Measuring method : Potential measurement
Measuring range : ±1000mv
Resolution : 1mv
Memory : Mass storage
Space between testing points : 1~100cm adjustable
Interface : RS232 and USB
Power supply : AA batteries (LR6)×6
Operating temperature : -10℃~+40℃
Relative humidity : <90%RH
Dimensions
Main unit : 210mm×153mm×90mm
Probe : Φ30mm×120mm
Weight
Main unit : 880g
Probe : 100g