TenmarsTM-802 Vibration Meter TM-802 Tenmar | Alat ukur vibrasi / getaran

Rp.13.500.000,-

Application:

This meter measures the vibrations of the rotating and reciprocating machines, as well as bearing damage, measurement items are acceleration, speed, displacement,  which can check if the machine is to be repaired or upgrade.

Features:

  • The maximum display of the LCD is 1999.
  • Measurement item: VEL (velocity) / ACC (acceleration) / DISP (displacement).
  • Function: Acceleration (RMS, PEAK, MAX, HOLD).
    Velocity (RMS, PEAK, MAX, HOLD).
    Displacement (P-P, MAX HOLD P-P, HOLD).
  • Unit: Acceleration: m/s², g, ft/s². Velocity: mm/s, cm/s, inch/s. Displacement: mm, inch.
  • Vibration sensor with magnetic adapter on1.2M (47.2) cable
  • Frequency Lo range :10Hz~1KHz meets ISO 2954 measurement
                     Hi range : 10Hz~5KHz
  • Overload display: “OL”.
  • Offset adjustment used for zero function
  • Auto power (15 minutes) and disable auto power off.
  • Resolution:0.1m/s²,0.01g,1ft/s²,0.1mm/s,0.01cm/s,0.01inch/s,0.001mm,0.001inch
  • High sensitivity probe head for accurate measurement.
  • Provides long and short probe head.
  • Frequency LO range: 10Hz-1KHz
  • Stores 99records manually.(ST-140)
  • Data logger with 9999 records capacity.(ST-140D)
  • USB interface.(ST-140D)

Specifications :

  • Dimensions:156x73x35mm(length x width x height).
  • Weight: Approximately 400 grams.(inchluding holster and accelerometer)

Electrical Specifications:
Accurate environmental conditions are: 23°C ± 3°C and RH <80%
Acceleration (RMS,PEAK,MAX HOLD)    1g=9.81m/S²

Range: 0.5~199.9 m/S² / 0.05~20.39g / 2〜656 ft/S²

Resolution: 0.1 m/s² / 0.01g / 1 ft/S²

Accuracy: ±(5%+5d)@79.4Hz and 158Hz / ±(5%+5d)@79.4Hz and 158Hz / ±(5%+5d) @79.4Hz and 158Hz

Calibration point: 50m/S² (158Hz) / 50m/S²{158Hz) / 50m/S²(158Hz)

Velocity VEL (RMS, PEAK, MAX HOLD)

Range: 0.5~199.9mm/s / 0.05~19.99cm/s / 0.02~7.87inch/s

Resolution : 0.1 mm/s / 0.01cm/s / 0.01inch/s

Accuracy: ± (5%+5d) @79.4Hz and 158Hz / ± (5%+5d)@79.4Hz and 158Hz / ± (5%+5d) @79.4Hz and 158Hz

Calibration point: 50m/s(158Hz) / 50m/s(158Hz) /  50m/s(158Hz)

Displacement DISP (P-P, MAX HOLD P-P)

Unit: mm / inch

Range: 0.005~1.999 mm / 0.002~0.078 inch

Resolution: 0.001 mm / 0.001 inch

Degree of error: ± (5%+5d)@79.4Hzand158Hz / ± (5%+5d)@79.4Hzand158Hz